Smoke vent rooflights (AOVs) in South Yorkshire: the essentials
Smoke vent rooflights (AOVs) in South Yorkshire means automatic smoke ventilators at the head of stairwells and atria. Every quote follows a survey of the roof and the room below.
Exposed Pennine and coastal towns in Yorkshire need upstand and flashing details built for wind-driven rain. Converted barns and mills in Yorkshire often suit bespoke or ridge rooflights that follow the original structure.
Towns in South Yorkshire
Specification options in South Yorkshire
- Break-glass and smoke-detector triggers
- Control panel with battery backup
- Glazed rooflight or louvred vent
- Service and test plans
- Electric (24 V) or pneumatic actuation
- Also usable for day-to-day ventilation
- Glazed units bring daylight to stairwells
Planning and building rules in England
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fragile-roof safety and access are planned before work starts.
Guide prices
Prices below are shown including and excluding VAT. In South Yorkshire, as elsewhere, making good inside and access equipment are the main variables.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
How the job runs
- Tell us about the roof. Send the postcode, rough sizes and a photo or two through the form, WhatsApp or the guide-price tool.
- Free survey. For new installations a surveyor measures the opening, checks the roof build-up and talks through glass and options.
- Fixed written quote. You get the product, the work and the price in writing. Nothing is ordered or paid for until you agree.
- Fitting and handover. We fit, seal and make good, then hand over product data, warranties and any certificate paperwork.
Smoke vents in nearby areas
Common questions
Who is responsible for maintaining smoke vents?
The responsible person (or duty holder in Scotland, appropriate person in Northern Ireland) for the building must keep fire safety systems maintained. We can arrange servicing and keep records.
Do you design the smoke strategy?
No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.
Do smoke vents need a control panel?
Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
Do I need to be at home for the survey in South Yorkshire?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.