How we approach smoke vent rooflights (AOVs) in Ammanford
Smoke vent rooflights (AOVs) in Ammanford means automatic smoke ventilators at the head of stairwells and atria. We cover the SA18 district and the rest of Dyfed, with a survey before any price is fixed.
Wales sees a lot of wind-driven rain, particularly in the west, so upstand height and flashing laps matter more than anywhere. Typical uses for smoke vent rooflights (AOVs) include communal stairwells, corridors and atria.
Jobs in Ammanford are planned around access: whether the roof can be reached from the garden, whether a hoist or crane is needed, and where we can park. We check this when we measure.
What you can choose
- Glazed rooflight or louvred vent
- Service and test plans
- Rain and wind sensors for daily vent use
- Control panel with battery backup
- Electric (24 V) or pneumatic actuation
- Also usable for day-to-day ventilation
- Servicing and testing available
Things we check at survey
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Replacing a vent with a non-equivalent product can affect the fire strategy
Building control and safety duties in Ammanford
Smoke vents are life-safety equipment: in Wales the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005 (as it applies in Wales). We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For non-domestic buildings in Wales, Approved Document L sets limiting U-values for rooflights and roof ventilators; we supply the manufacturer's data for the building control submission. Fire classification of rooflight materials near boundaries is checked at specification.
Our planning guide covers each nation in more detail.
Smoke vent rooflights (AOVs) prices in Ammanford
These are typical supply-and-fit ranges. For an address in Ammanford, scaffold, a hoist for heavy glass, or a new structural opening can move the figure, which is why we survey first.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
From enquiry to finished job
- Send the details. Postcode, rough size and a photo of the roof and room.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Agree the quote. You approve the specification and price before anything is ordered.
- Installation day. Usually one day into a prepared opening, longer for new openings.
Nearby towns
Related work in Ammanford
Questions about smoke vent rooflights (AOVs) in Ammanford
Do smoke vents need a control panel?
Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
How do I book a survey in Ammanford?
Send your postcode and, if you can, a photo of the roof and the room. We offer a survey date when we reply.
Can you work alongside my builder in Ammanford?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.