Smoke vent rooflights (AOVs) in Coulsdon: what is involved?
For Coulsdon homes and buildings we offer smoke vent rooflights (AOVs): automatic smoke ventilators at the head of stairwells and atria. We measure first, specify to the opening and confirm any planning or building-control points before quoting.
London homes often run deep from front to back, so the middle of the ground floor is the darkest space — exactly where an overhead rooflight earns its keep. Think of smoke vent rooflights (AOVs) for blocks of flats and commercial buildings with a smoke strategy.
Coulsdon sits about 3 km from Purley and 5 km from Banstead, and we cover the whole CR5 postcode district and the roads in between.
Options we can specify in Coulsdon
- Service and test plans
- Break-glass and smoke-detector triggers
- Control panel with battery backup
- Rain and wind sensors for daily vent use
- Electric (24 V) or pneumatic actuation
- Also usable for day-to-day ventilation
- Servicing and testing available
What to check first
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Replacing a vent with a non-equivalent product can affect the fire strategy
Building control and safety duties in Coulsdon
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fire classification of rooflight materials near boundaries is checked at specification.
See our building regulations guide for U-values, glazing limits and self-certification.
Guide prices for Coulsdon
The ranges below are typical for straightforward jobs; your fixed price follows a survey of your roof.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
From enquiry to finished job
- Send the details. Postcode, rough size and a photo of the roof and room.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Fit and make good. We fit, seal, test and finish the reveal, then hand over the paperwork.
Smoke vent rooflights (AOVs) near Coulsdon
Related work in Coulsdon
Common questions
Do you design the smoke strategy?
No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
Do smoke vents need a control panel?
Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.
Do I need to be at home for the survey in Coulsdon?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.
Do you fit smoke vent rooflights (AOVs) in Coulsdon?
Yes. We survey and fit smoke vent rooflights (AOVs) in Coulsdon and across Greater London. Send your postcode and we will offer a survey date when we reply.