Smoke vent rooflights (AOVs) in Greenford: what is involved?
We handle smoke vent rooflights (AOVs) across Greater London, including Greenford. In short: automatic smoke ventilators at the head of stairwells and atria. The survey checks structure, weathering and orientation, so the quote reflects your actual roof.
Party walls are a fact of life in London terraces, and rooflights close to a shared wall need detailing that keeps the neighbour's side dry too. Typical uses for smoke vent rooflights (AOVs) include blocks of flats and commercial buildings with a smoke strategy.
Greenford is around 16 km from central London, and we survey and fit throughout that part of Greater London, including the UB6 district.
Specification options
- Glazed rooflight or louvred vent
- Rain and wind sensors for daily vent use
- Electric (24 V) or pneumatic actuation
- Service and test plans
- Control panel with battery backup
- Also usable for day-to-day ventilation
- Manual override at the fire service access level
Before you order: points to check
- Smoke ventilation is designed to the building's fire strategy — we install to that design
- Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested
Regulations for smoke vent rooflights (AOVs) in Greenford
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fire classification of rooflight materials near boundaries is checked at specification.
Read the planning permission guide before you commit to a design.
Smoke vent rooflights (AOVs) prices in Greenford
The ranges below are typical for straightforward jobs; your fixed price follows a survey of your roof.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
From enquiry to finished job
- Send the details. Postcode, rough size and a photo of the roof and room.
- Survey. We measure the opening, check the roof build-up and agree the options.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Fitting and handover. We install, clean down and leave product and warranty documents.
Nearby towns
Other services in Greenford
Smoke vent rooflights (AOVs) in Greenford: questions
Can a smoke vent be used for normal ventilation?
Many dual-purpose units also open for daily ventilation, closing automatically in rain.
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
Can you work alongside my builder in Greenford?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.
Do I need to be at home for the survey in Greenford?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.