Smoke vent rooflights (AOVs) for Urmston: the essentials
For Urmston homes and buildings we offer smoke vent rooflights (AOVs): automatic smoke ventilators at the head of stairwells and atria. We measure first, specify to the opening and confirm any planning or building-control points before quoting.
Converted mills and warehouses in the North West often have large rooflights or glass roofs that need specialist replacement. Typical uses for smoke vent rooflights (AOVs) include blocks of flats and commercial buildings with a smoke strategy.
Neighbouring towns include Stretford (2 km) and Sale (3 km). We offer a survey date when we reply to your enquiry.
What you can choose
- Electric (24 V) or pneumatic actuation
- Rain and wind sensors for daily vent use
- Break-glass and smoke-detector triggers
- Service and test plans
- Control panel with battery backup
- Opens automatically on alarm signal
- Replacement of failed or obsolete units
Things we check at survey
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested
Rules and responsibilities in Urmston
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fire classification of rooflight materials near boundaries is checked at specification.
Read the planning permission guide before you commit to a design.
Smoke vent rooflights (AOVs) prices in Urmston
The ranges below are typical for straightforward jobs; your fixed price follows a survey of your roof.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
The process, step by step
- Tell us what you have. Send the M41 postcode, a rough size and a couple of photos.
- Survey. We measure the opening, check the roof build-up and agree the options.
- Agree the quote. You approve the specification and price before anything is ordered.
- Fitting and handover. We install, clean down and leave product and warranty documents.
Nearby towns
More we do in Urmston
Smoke vent rooflights (AOVs) in Urmston: questions
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
Can a smoke vent be used for normal ventilation?
Many dual-purpose units also open for daily ventilation, closing automatically in rain.
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
How do I book a survey in Urmston?
Send your postcode and, if you can, a photo of the roof and the room. We offer a survey date when we reply.
Can you work alongside my builder in Urmston?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.