Free survey for new installsFixed written quoteEngland, Wales, Scotland & NI
Call 0800 088 6248
SkylightCompany.uk
Smoke vents · Herefordshire

Smoke vent rooflights (AOVs) in Leominster

Planning smoke vent rooflights (AOVs) in Leominster? We cover the whole of Herefordshire, with a fixed written quote and the upstand or flashing detail done properly.

  • Free survey for new installations
  • Covering HR6 and all of Herefordshire
  • Upstand, flashing and making good set out in your quote

Quote for Leominster

Free survey for new installs · we aim to reply within one working day

Enter a UK postcode.
Choose an option.
Enter your name.
Enter a phone number we can call.
Check the email address.

We use your details to answer this enquiry and arrange your survey. They pass through our form, chat and hosting providers and are shared only with the surveyor or installer working for us on your job — see our privacy notice.

HR6Postcode district
HerefordshireCounty / region
17 kmto Ludlow
£2,995Guide price from (inc VAT)

Smoke vent rooflights (AOVs) in Leominster: what is involved?

Our smoke vent rooflights (AOVs) service in Leominster covers automatic smoke ventilators at the head of stairwells and atria. Every job starts with a survey of the opening, the roof covering and the room below, and a fixed written price.

Older terraced streets in Midlands towns often have back additions and side passages that suit a ridge rooflight or long flat rooflight. Smoke vent rooflights (AOVs) suit blocks of flats and commercial buildings with a smoke strategy.

We work across Herefordshire, including Leominster, and in neighbouring towns such as Ludlow and Hereford. Access, parking and how the glass reaches the roof are all checked at the survey.

Specification options

  • Electric (24 V) or pneumatic actuation
  • Break-glass and smoke-detector triggers
  • Control panel with battery backup
  • Rain and wind sensors for daily vent use
  • Service and test plans
  • Replacement of failed or obsolete units
  • Opens automatically on alarm signal

Things we check at survey

  • Smoke ventilation is designed to the building's fire strategy — we install to that design
  • Replacing a vent with a non-equivalent product can affect the fire strategy

Building control and safety duties in Leominster

Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.

For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fire classification of rooflight materials near boundaries is checked at specification.

See our building regulations guide for U-values, glazing limits and self-certification.

Guide prices for Leominster

Prices below are shown including and excluding VAT. In Leominster, as elsewhere, making good inside and access equipment are the main variables.

OptionGuide price inc VATEx VAT
Large glazed AOV with actuators£4,795 – £7,795£3,995 – £6,495
Standard glazed AOV Typical£3,595 – £4,795£2,995 – £3,995
Replacement vent onto existing upstand£2,995 – £3,595£2,495 – £2,995

How the job runs

  1. Get in touch. Use the form, WhatsApp or the guide-price tool with your Leominster address.
  2. Survey. We measure the opening, check the roof build-up and agree the options.
  3. Written price. You receive a fixed price listing the unit, the work and the lead time.
  4. Fit and make good. We fit, seal, test and finish the reveal, then hand over the paperwork.

Neighbouring towns

More we do in Leominster

Smoke vent rooflights (AOVs) in Leominster: questions

How often should AOVs be tested?

Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.

Do you design the smoke strategy?

No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.

Do smoke vents need a control panel?

Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.

Do you fit smoke vent rooflights (AOVs) in Leominster?

Yes. We survey and fit smoke vent rooflights (AOVs) in Leominster and across Herefordshire. Send your postcode and we will offer a survey date when we reply.

Can you work alongside my builder in Leominster?

Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.

Free survey · fixed written quote

Get a fixed price for your rooflight

Tell us where you are and what you have in mind. We aim to reply within one working day.

CallFree quote