Smoke vent rooflights (AOVs) for Chorley: the essentials
We handle smoke vent rooflights (AOVs) across Lancashire, including Chorley. In short: automatic smoke ventilators at the head of stairwells and atria. The survey checks structure, weathering and orientation, so the quote reflects your actual roof.
The North West gets more rain than most of England, so upstand height, membrane detailing and rain sensors on opening units are not optional extras. Smoke vent rooflights (AOVs) suit blocks of flats and commercial buildings with a smoke strategy.
Chorley sits about 7 km from Leyland and 11 km from Darwen, and we cover the whole PR7 postcode district and the roads in between.
Choices for your Chorley project
- Rain and wind sensors for daily vent use
- Service and test plans
- Glazed rooflight or louvred vent
- Break-glass and smoke-detector triggers
- Electric (24 V) or pneumatic actuation
- Replacement of failed or obsolete units
- Also usable for day-to-day ventilation
Before you order: points to check
- Replacing a vent with a non-equivalent product can affect the fire strategy
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
Building control and safety duties in Chorley
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fire classification of rooflight materials near boundaries is checked at specification.
Read the planning permission guide before you commit to a design.
Guide prices for Chorley
Prices below are shown including and excluding VAT. In Chorley, as elsewhere, making good inside and access equipment are the main variables.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
How the job runs
- Get in touch. Use the form, WhatsApp or the guide-price tool with your Chorley address.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Fit and make good. We fit, seal, test and finish the reveal, then hand over the paperwork.
Neighbouring towns
More we do in Chorley
Questions about smoke vent rooflights (AOVs) in Chorley
Can a smoke vent be used for normal ventilation?
Many dual-purpose units also open for daily ventilation, closing automatically in rain.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
How do I book a survey in Chorley?
Send your postcode and, if you can, a photo of the roof and the room. We offer a survey date when we reply.
Do you fit smoke vent rooflights (AOVs) in Chorley?
Yes. We survey and fit smoke vent rooflights (AOVs) in Chorley and across Lancashire. Send your postcode and we will offer a survey date when we reply.