Smoke vent rooflights (AOVs) for Northwich: the essentials
Thinking about smoke vent rooflights (AOVs) in Northwich? The short answer: automatic smoke ventilators at the head of stairwells and atria. The longer answer depends on your roof, which is why we survey before we price.
Stone and brick terraces are typical across the North West, and roof windows in rear slopes are a common way to light attic rooms. Typical uses for smoke vent rooflights (AOVs) include communal stairwells, corridors and atria.
Northwich sits about 7 km from Winsford and 15 km from Warrington, and we cover the whole CW9 postcode district and the roads in between.
What you can choose
- Service and test plans
- Rain and wind sensors for daily vent use
- Control panel with battery backup
- Electric (24 V) or pneumatic actuation
- Glazed rooflight or louvred vent
- Manual override at the fire service access level
- Glazed units bring daylight to stairwells
Before you order: points to check
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested
Rules and responsibilities in Northwich
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We install to the building's fire strategy and the manufacturer's certification.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fragile-roof safety and access are planned before work starts.
Our planning guide covers each nation in more detail.
Guide prices for Northwich
The ranges below are typical for straightforward jobs; your fixed price follows a survey of your roof.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
How the job runs
- Tell us what you have. Send the CW9 postcode, a rough size and a couple of photos.
- Survey. We measure the opening, check the roof build-up and agree the options.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Installation day. Usually one day into a prepared opening, longer for new openings.
Smoke vent rooflights (AOVs) near Northwich
More we do in Northwich
Common questions
Who is responsible for maintaining smoke vents?
The responsible person (or duty holder in Scotland, appropriate person in Northern Ireland) for the building must keep fire safety systems maintained. We can arrange servicing and keep records.
Do smoke vents need a control panel?
Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.
Can a smoke vent be used for normal ventilation?
Many dual-purpose units also open for daily ventilation, closing automatically in rain.
Can you work alongside my builder in Northwich?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.
Do I need to be at home for the survey in Northwich?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.