How we approach smoke vent rooflights (AOVs) in Altrincham
We handle smoke vent rooflights (AOVs) across Greater Manchester, including Altrincham. In short: automatic smoke ventilators at the head of stairwells and atria. The survey checks structure, weathering and orientation, so the quote reflects your actual roof.
Stone and brick terraces are typical across the North West, and roof windows in rear slopes are a common way to light attic rooms. In Altrincham, as anywhere, smoke vent rooflights (AOVs) are the usual choice for communal stairwells, corridors and atria.
Altrincham is around 13 km from Manchester, and we survey and fit throughout that part of Greater Manchester, including the WA14 district.
What you can choose
- Service and test plans
- Glazed rooflight or louvred vent
- Control panel with battery backup
- Electric (24 V) or pneumatic actuation
- Break-glass and smoke-detector triggers
- Servicing and testing available
- Manual override at the fire service access level
What to check first
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested
Building control and safety duties in Altrincham
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fragile-roof safety and access are planned before work starts.
See our building regulations guide for U-values, glazing limits and self-certification.
Smoke vent rooflights (AOVs) prices in Altrincham
These are typical supply-and-fit ranges. For an address in Altrincham, scaffold, a hoist for heavy glass, or a new structural opening can move the figure, which is why we survey first.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
How the job runs
- Get in touch. Use the form, WhatsApp or the guide-price tool with your Altrincham address.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Installation day. Usually one day into a prepared opening, longer for new openings.
Nearby towns
Related work in Altrincham
Common questions
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
Do you design the smoke strategy?
No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.
Who is responsible for maintaining smoke vents?
The responsible person (or duty holder in Scotland, appropriate person in Northern Ireland) for the building must keep fire safety systems maintained. We can arrange servicing and keep records.
Do I need to be at home for the survey in Altrincham?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.
Can you work alongside my builder in Altrincham?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.