Smoke vent rooflights (AOVs) for Craigavon: the essentials
For Craigavon homes and buildings we offer smoke vent rooflights (AOVs): automatic smoke ventilators at the head of stairwells and atria. We measure first, specify to the opening and confirm any planning or building-control points before quoting.
Northern Ireland has a mix of terraces, bungalows and rural farmhouses, and rooflights are a common upgrade when extending. Think of smoke vent rooflights (AOVs) for communal stairwells, corridors and atria.
We cover all of Craigavon and the BT62 district, and nearby Lurgan and Portadown.
Choices for your Craigavon project
- Service and test plans
- Rain and wind sensors for daily vent use
- Electric (24 V) or pneumatic actuation
- Break-glass and smoke-detector triggers
- Control panel with battery backup
- Manual override at the fire service access level
- Also usable for day-to-day ventilation
Things we check at survey
- Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested
- Replacing a vent with a non-equivalent product can affect the fire strategy
Regulations for smoke vent rooflights (AOVs) in Craigavon
Smoke vents are life-safety equipment: in Northern Ireland the appropriate person must keep them maintained under the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010. We install to the building's fire strategy and the manufacturer's certification.
For non-domestic buildings in Northern Ireland, Technical Booklet F2 covers energy performance; we supply the manufacturer's data for building control. Fire classification of rooflight materials near boundaries is checked at specification.
Read the planning permission guide before you commit to a design.
Guide prices for Craigavon
The ranges below are typical for straightforward jobs; your fixed price follows a survey of your roof.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
The process, step by step
- Tell us what you have. Send the BT62 postcode, a rough size and a couple of photos.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Installation day. Usually one day into a prepared opening, longer for new openings.
Nearby towns
Related work in Craigavon
Questions about smoke vent rooflights (AOVs) in Craigavon
Who is responsible for maintaining smoke vents?
The responsible person (or duty holder in Scotland, appropriate person in Northern Ireland) for the building must keep fire safety systems maintained. We can arrange servicing and keep records.
Do you design the smoke strategy?
No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
Do you fit smoke vent rooflights (AOVs) in Craigavon?
Yes. We survey and fit smoke vent rooflights (AOVs) in Craigavon and across County Armagh. Send your postcode and we will offer a survey date when we reply.
Do I need to be at home for the survey in Craigavon?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.