What do smoke vent rooflights (AOVs) in Stratford involve?
We handle smoke vent rooflights (AOVs) across Greater London, including Stratford. In short: automatic smoke ventilators at the head of stairwells and atria. The survey checks structure, weathering and orientation, so the quote reflects your actual roof.
Party walls are a fact of life in London terraces, and rooflights close to a shared wall need detailing that keeps the neighbour's side dry too. Typical uses for smoke vent rooflights (AOVs) include communal stairwells, corridors and atria.
Jobs in Stratford are planned around access: whether the roof can be reached from the garden, whether a hoist or crane is needed, and where we can park. We check this when we measure.
Specification options
- Glazed rooflight or louvred vent
- Electric (24 V) or pneumatic actuation
- Service and test plans
- Break-glass and smoke-detector triggers
- Control panel with battery backup
- Manual override at the fire service access level
- Glazed units bring daylight to stairwells
Things we check at survey
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Smoke ventilation is designed to the building's fire strategy — we install to that design
Regulations for smoke vent rooflights (AOVs) in Stratford
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fragile-roof safety and access are planned before work starts.
See our building regulations guide for U-values, glazing limits and self-certification.
Guide prices for Stratford
The ranges below are typical for straightforward jobs; your fixed price follows a survey of your roof.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
From enquiry to finished job
- Send the details. Postcode, rough size and a photo of the roof and room.
- Measure and check. A surveyor visits Stratford, measures and checks structure and access.
- Written price. You receive a fixed price listing the unit, the work and the lead time.
- Installation day. Usually one day into a prepared opening, longer for new openings.
Smoke vent rooflights (AOVs) near Stratford
Related work in Stratford
Common questions
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
Do you design the smoke strategy?
No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.
Do smoke vents need a control panel?
Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.
Can you work alongside my builder in Stratford?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.
Do you fit smoke vent rooflights (AOVs) in Stratford?
Yes. We survey and fit smoke vent rooflights (AOVs) in Stratford and across Greater London. Send your postcode and we will offer a survey date when we reply.