How we approach smoke vent rooflights (AOVs) in Staines
We handle smoke vent rooflights (AOVs) across Surrey, including Staines. In short: automatic smoke ventilators at the head of stairwells and atria. The survey checks structure, weathering and orientation, so the quote reflects your actual roof.
Many South East homes have been extended more than once, and an old dome over an earlier extension is often due for replacement. Think of smoke vent rooflights (AOVs) for communal stairwells, corridors and atria.
Jobs in Staines are planned around access: whether the roof can be reached from the garden, whether a hoist or crane is needed, and where we can park. We check this when we measure.
Options we can specify in Staines
- Break-glass and smoke-detector triggers
- Rain and wind sensors for daily vent use
- Glazed rooflight or louvred vent
- Electric (24 V) or pneumatic actuation
- Control panel with battery backup
- Glazed units bring daylight to stairwells
- Opens automatically on alarm signal
Things we check at survey
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
- Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested
Rules and responsibilities in Staines
Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We install to the building's fire strategy and the manufacturer's certification.
For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fire classification of rooflight materials near boundaries is checked at specification.
See our building regulations guide for U-values, glazing limits and self-certification.
Guide prices for Staines
Guide prices for smoke vent rooflights (AOVs) in Staines are the same as anywhere we work — what changes the price is the job: access, structure, scaffold and finishing.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
What happens next
- Send the details. Postcode, rough size and a photo of the roof and room.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Agree the quote. You approve the specification and price before anything is ordered.
- Installation day. Usually one day into a prepared opening, longer for new openings.
Neighbouring towns
Related work in Staines
Common questions
Can a smoke vent be used for normal ventilation?
Many dual-purpose units also open for daily ventilation, closing automatically in rain.
Do you design the smoke strategy?
No — the strategy comes from the building's fire engineer or designer. We supply, install, commission and service to it.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
Do I need to be at home for the survey in Staines?
Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.
How do I book a survey in Staines?
Send your postcode and, if you can, a photo of the roof and the room. We offer a survey date when we reply.