Free survey for new installsFixed written quoteEngland, Wales, Scotland & NI
Call 0800 088 6248
SkylightCompany.uk
Smoke vents · West Midlands

Smoke vent rooflights (AOVs) in Wolverhampton

Smoke vent rooflights (AOVs) in Wolverhampton (WV1) and across the West Midlands: surveyed, specified to the opening and priced in writing before any work starts.

  • Planning and building-regs points explained
  • Upstand, flashing and making good set out in your quote
  • Fixed price in writing before work starts

Quote for Wolverhampton

Free survey for new installs · we aim to reply within one working day

Enter a UK postcode.
Choose an option.
Enter your name.
Enter a phone number we can call.
Check the email address.

We use your details to answer this enquiry and arrange your survey. They pass through our form, chat and hosting providers and are shared only with the surveyor or installer working for us on your job — see our privacy notice.

WV1Postcode district
West MidlandsCounty / region
3 kmto Wednesfield
£2,995Guide price from (inc VAT)

Smoke vent rooflights (AOVs) in Wolverhampton: what is involved?

For Wolverhampton homes and buildings we offer smoke vent rooflights (AOVs): automatic smoke ventilators at the head of stairwells and atria. We measure first, specify to the opening and confirm any planning or building-control points before quoting.

Many Midlands semis have had a single-storey rear extension added, and a larger flat rooflight or lantern is often the change that makes it feel finished. In Wolverhampton, as anywhere, smoke vent rooflights (AOVs) are the usual choice for blocks of flats and commercial buildings with a smoke strategy.

Wolverhampton is around 19 km from Birmingham, and we survey and fit throughout that part of the West Midlands, including the WV1 district.

Choices for your Wolverhampton project

  • Service and test plans
  • Break-glass and smoke-detector triggers
  • Glazed rooflight or louvred vent
  • Rain and wind sensors for daily vent use
  • Electric (24 V) or pneumatic actuation
  • Also usable for day-to-day ventilation
  • Glazed units bring daylight to stairwells

Before you order: points to check

  • The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
  • Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested

Regulations for smoke vent rooflights (AOVs) in Wolverhampton

Smoke vents are life-safety equipment: in England the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005. We install to the building's fire strategy and the manufacturer's certification.

For buildings other than dwellings, Approved Document L Volume 2 sets limiting U-values of 2.2 W/m²K for rooflights and 3.0 W/m²K for roof ventilators, including smoke vents. Fragile-roof safety and access are planned before work starts.

Our planning guide covers each nation in more detail.

Guide prices for Wolverhampton

Prices below are shown including and excluding VAT. In Wolverhampton, as elsewhere, making good inside and access equipment are the main variables.

OptionGuide price inc VATEx VAT
Large glazed AOV with actuators£4,795 – £7,795£3,995 – £6,495
Standard glazed AOV Typical£3,595 – £4,795£2,995 – £3,995
Replacement vent onto existing upstand£2,995 – £3,595£2,495 – £2,995

The process, step by step

  1. Get in touch. Use the form, WhatsApp or the guide-price tool with your Wolverhampton address.
  2. Measure and check. A surveyor visits Wolverhampton, measures and checks structure and access.
  3. Written price. You receive a fixed price listing the unit, the work and the lead time.
  4. Installation day. Usually one day into a prepared opening, longer for new openings.

Smoke vent rooflights (AOVs) near Wolverhampton

More we do in Wolverhampton

Common questions

Do smoke vents need a control panel?

Electric AOVs work with a control panel that links them to detectors, the fire alarm and override switches.

Who is responsible for maintaining smoke vents?

The responsible person (or duty holder in Scotland, appropriate person in Northern Ireland) for the building must keep fire safety systems maintained. We can arrange servicing and keep records.

How often should AOVs be tested?

Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.

Do I need to be at home for the survey in Wolverhampton?

Yes — someone needs to let us into the room below and, where possible, show us how the roof is reached.

Can you work alongside my builder in Wolverhampton?

Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.

Free survey · fixed written quote

Ready for more daylight?

Tell us where you are and what you have in mind. We aim to reply within one working day.

CallFree quote