What do smoke vent rooflights (AOVs) in Peterhead involve?
Our smoke vent rooflights (AOVs) service in Peterhead covers automatic smoke ventilators at the head of stairwells and atria. Every job starts with a survey of the opening, the roof covering and the room below, and a fixed written price.
Scottish weather is hard on roofs, so we specify rooflights and roof windows with exposure in mind and fit upstands with generous heights. In Peterhead, as anywhere, smoke vent rooflights (AOVs) are the usual choice for blocks of flats and commercial buildings with a smoke strategy.
Jobs in Peterhead are planned around access: whether the roof can be reached from the garden, whether a hoist or crane is needed, and where we can park. We check this when we measure.
Options we can specify in Peterhead
- Glazed rooflight or louvred vent
- Electric (24 V) or pneumatic actuation
- Break-glass and smoke-detector triggers
- Control panel with battery backup
- Service and test plans
- Manual override at the fire service access level
- Opens automatically on alarm signal
Things we check at survey
- Replacing a vent with a non-equivalent product can affect the fire strategy
- The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
Building control and safety duties in Peterhead
Smoke vents are life-safety equipment: in Scotland the duty holder must keep them maintained under the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006. We install to the building's fire strategy and the manufacturer's certification.
For non-domestic buildings in Scotland, the non-domestic Technical Handbook (section 6) sets the energy standards for rooflights; we supply the manufacturer's data for the building warrant. Fragile-roof safety and access are planned before work starts.
See our building regulations guide for U-values, glazing limits and self-certification.
Guide prices for Peterhead
Prices below are shown including and excluding VAT. In Peterhead, as elsewhere, making good inside and access equipment are the main variables.
| Option | Guide price inc VAT | Ex VAT |
|---|---|---|
| Large glazed AOV with actuators | £4,795 – £7,795 | £3,995 – £6,495 |
| Standard glazed AOV Typical | £3,595 – £4,795 | £2,995 – £3,995 |
| Replacement vent onto existing upstand | £2,995 – £3,595 | £2,495 – £2,995 |
The process, step by step
- Get in touch. Use the form, WhatsApp or the guide-price tool with your Peterhead address.
- Free site visit. For new installs we survey free, measure and confirm the roof detail.
- Agree the quote. You approve the specification and price before anything is ordered.
- Fit and make good. We fit, seal, test and finish the reveal, then hand over the paperwork.
Neighbouring towns
Related work in Peterhead
Smoke vent rooflights (AOVs) in Peterhead: questions
Can a smoke vent be used for normal ventilation?
Many dual-purpose units also open for daily ventilation, closing automatically in rain.
Can you replace an old smoke vent?
Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.
How often should AOVs be tested?
Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.
Can you work alongside my builder in Peterhead?
Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.
How do I book a survey in Peterhead?
Send your postcode and, if you can, a photo of the roof and the room. We offer a survey date when we reply.