Free survey for new installsFixed written quoteEngland, Wales, Scotland & NI
Call 0800 088 6248
SkylightCompany.uk
Smoke vents · Powys

Smoke vent rooflights (AOVs) in Brecon

Planning smoke vent rooflights (AOVs) in Brecon? We cover the whole of Powys, with a fixed written quote and the upstand or flashing detail done properly.

  • Planning and building-regs points explained
  • Covering LD3 and all of Powys
  • Fixed price in writing before work starts

Quote for Brecon

Free survey for new installs · we aim to reply within one working day

Enter a UK postcode.
Choose an option.
Enter your name.
Enter a phone number we can call.
Check the email address.

We use your details to answer this enquiry and arrange your survey. They pass through our form, chat and hosting providers and are shared only with the surveyor or installer working for us on your job — see our privacy notice.

LD3Postcode district
PowysCounty / region
22 kmto Merthyr Tydfil
£2,995Guide price from (inc VAT)

What do smoke vent rooflights (AOVs) in Brecon involve?

Our smoke vent rooflights (AOVs) service in Brecon covers automatic smoke ventilators at the head of stairwells and atria. Every job starts with a survey of the opening, the roof covering and the room below, and a fixed written price.

Many Welsh homes have older single-storey rear extensions where a glass rooflight brightens a dark kitchen. In Brecon, as anywhere, smoke vent rooflights (AOVs) are the usual choice for blocks of flats and commercial buildings with a smoke strategy.

Brecon sits about 22 km from Merthyr Tydfil and 23 km from Ebbw Vale, and we cover the whole LD3 postcode district and the roads in between.

What you can choose

  • Service and test plans
  • Rain and wind sensors for daily vent use
  • Electric (24 V) or pneumatic actuation
  • Control panel with battery backup
  • Break-glass and smoke-detector triggers
  • Servicing and testing available
  • Replacement of failed or obsolete units

What to check first

  • The product should be certified to BS EN 12101-2 as a natural smoke and heat exhaust ventilator
  • Whoever holds the building's fire-safety duties (the responsible person, the duty holder in Scotland or the appropriate person in Northern Ireland) must keep systems maintained and tested

Rules and responsibilities in Brecon

Smoke vents are life-safety equipment: in Wales the responsible person must keep them maintained under the Regulatory Reform (Fire Safety) Order 2005 (as it applies in Wales). We supply manufacturer-certified units and arrange installation, commissioning and servicing through specialist smoke-control engineers.

For non-domestic buildings in Wales, Approved Document L sets limiting U-values for rooflights and roof ventilators; we supply the manufacturer's data for the building control submission. Fire classification of rooflight materials near boundaries is checked at specification.

Read the planning permission guide before you commit to a design.

Guide prices for Brecon

Prices below are shown including and excluding VAT. In Brecon, as elsewhere, making good inside and access equipment are the main variables.

OptionGuide price inc VATEx VAT
Large glazed AOV with actuators£4,795 – £7,795£3,995 – £6,495
Standard glazed AOV Typical£3,595 – £4,795£2,995 – £3,995
Replacement vent onto existing upstand£2,995 – £3,595£2,495 – £2,995

How the job runs

  1. Send the details. Postcode, rough size and a photo of the roof and room.
  2. Measure and check. A surveyor visits Brecon, measures and checks structure and access.
  3. Written price. You receive a fixed price listing the unit, the work and the lead time.
  4. Installation day. Usually one day into a prepared opening, longer for new openings.

Neighbouring towns

Other services in Brecon

Questions about smoke vent rooflights (AOVs) in Brecon

Can you replace an old smoke vent?

Yes, with an equivalent certified unit that matches the original design area and performance, so the fire strategy is not compromised.

How often should AOVs be tested?

Industry guidance recommends regular functional checks and at least annual servicing. Your fire risk assessment sets the regime.

Can a smoke vent be used for normal ventilation?

Many dual-purpose units also open for daily ventilation, closing automatically in rain.

Can you work alongside my builder in Brecon?

Yes. On new extensions we fit once the opening and upstand are ready and coordinate dates with your builder.

Do you fit smoke vent rooflights (AOVs) in Brecon?

Yes. We survey and fit smoke vent rooflights (AOVs) in Brecon and across Powys. Send your postcode and we will offer a survey date when we reply.

Free survey · fixed written quote

Plan the light before you build

Send a photo of the roof and a rough size — we will reply with options, a guide price and a survey date.

CallFree quote